How much firewood by state / South Atlantic
NOAA 1991-2020 normals · checked 2026-10-20
How much firewood for a South Carolina winter?
A 2,000 sq ft house built in the 1970s and heated only with wood burns about 1.9 cords in a normal South Carolina winter (5.8 face cords of 16-inch wood). South Carolina averages 2,587 heating degree days a year, the #43 coldest of the 48 states NOAA covers here, 52% below the median state.
- 1Cords per winter 1.9 cords
- 2Face cords (16 in) 5.8
- 3Degree days 2,587
- 4Coldest of 48 #43
Cords per winter in South Carolina by house size and age
The table uses a generic cord (20 million Btu, the EIA figure) burned in a 74% efficient stove, with wood as the only heat. House age stands in for insulation and air-tightness: it sets how much heat a home of that era used per square foot per degree day in the federal Residential Energy Consumption Survey.
| Floor area | Built 1990 or later | 1970s | Before 1950 |
|---|---|---|---|
| 1,000 sq ft | 0.7 | 1.0 | 1.2 |
| 1,500 sq ft | 1.0 | 1.5 | 1.9 |
| 2,000 sq ft | 1.3 | 1.9 | 2.5 |
| 2,500 sq ft | 1.7 | 2.4 | 3.1 |
South Carolina is one of the ten mildest states here, so wood heat goes a long way: a newer 2,000 sq ft house needs 1.3 cords, and even a pre-1950 house of that size needs 2.5. A small, newer home of 1,200 sq ft gets by on 0.8 cords. If the stove only supplements a furnace and supplies about half the heat, the example house needs 1.0 cords.
A cold winter versus a mild one
Thirty years of NOAA data show how much a single winter can swing. South Carolina's coldest year was 2010 with 3,211 degree days and its mildest was 2017 with 2,089, a spread of 43% of the average. For the example house that is the difference between 2.4 and 1.6 cords, so buying 0.5 cords more than the average year covers a winter like 2010. The last decade (2011–2020) averaged 2,431 degree days, 9% fewer than the first (1991–2000, 2,684).
Which wood, and what it costs
Dense hardwood shrinks the pile. For the example house in South Carolina:
- Hickory (29.3 million Btu per cord): 1.3 cords
- Red oak (25.9 million Btu per cord): 1.5 cords
- White pine (15 million Btu per cord): 2.6 cords
South Carolina has no dated cord price from a state agriculture or energy office, so this page does not quote one. Enter what local sellers charge in the calculator: the cost is simply cords × price. Ask whether a quote is for a full cord (128 cubic feet stacked) or a face cord, and whether the wood is seasoned; the cord guide shows how to compare quotes.
What size stove for South Carolina?
From its average-winter use, the example house loses about 30,049 BTU/h on a 0°F night (an estimate, not a room-by-room heat-loss calculation). 6 stoves listed here are rated by their makers for 2,000 sq ft, and all of them publish an output at or above that figure, for example the Pacific Energy Super LE (72,000 BTU/h). Makers rate area for an open, reasonably insulated layout; a chopped-up floor plan or a leaky older house needs more. See stove sizes for 1,200 to 2,000 sq ft or pick your own floor area on the stove size chart. Have the chimney swept and inspected every year (U.S. Fire Administration); the chimney guide explains why.
Nearby states
West Virginia averages 5,067 degree days (3.8 cords for the example house); Maryland averages 4,563 degree days (3.4 cords for the example house); Delaware averages 4,483 degree days (3.4 cords for the example house); Virginia averages 4,259 degree days (3.2 cords for the example house); North Carolina averages 3,359 degree days (2.5 cords for the example house); Georgia averages 2,807 degree days (2.1 cords for the example house); Florida averages 646 degree days (0.5 cords for the example house).
Degree days: NOAA NCEI Climate at a Glance, South Carolina January-December Heating Degree Days (base 65°F), 1991-2020, checked 2026-10-20. Heat per square foot: EIA RECS 2001, Table CE2-2c; furnace efficiency used to turn that gas into heat: 78% (10 CFR 430.32). Full method on the methodology page. Estimates only; a house's real use depends on its insulation, air leaks, layout and how warm it is kept.